188
The fan keeps running after the drive is powered up.
2: Fun operates based on command
When the drive will operate normally upon receiving the running command, the fan will also operate.
When the drive stops running, so does the fan.
6.13 Multi-stage reference and simple PLC parameters (Group P13)
0: Multi-stage frequency reference
As a frequency mode, it is applied to multi-speed operation mode and simple PLC operation mode.
1: Multi-stage closed loop reference
As a voltage reference, it is applied to the process PID operation mode.
When it is the multi-stage frequency, its setting range can be set as 0.0%~100.0%, corresponding to zero
frequency to the maximum frequency. When used as multi-speed operation independently, its operating
direction is controlled by the running terminal. When the running terminal is forward output (FWD),
operate the forward frequency. When the running terminal is reverse output (REV), operate the reverse
frequency. The running direction shall be set correspondingly according to PLC while operating as PLC.
When it is the multi-stage closed loop reference, -100.0%~100.0% corresponds to -10V~+10V.
Multi-sta
e reference 15 -100.0~100.0%
100.0%
P13.15
Multi-sta
e reference 14
-100.0~100.0%
100.0%
P13.14
Multi-sta
e reference 13 -100.0~100.0%
90.0%
P13.13
Multi-sta
e reference 12 -100.0~100.0%
80.0%
P13.12
Multi-sta
e reference 11 -100.0~100.0%
60.0%
P13.11
Multi-sta
e reference 10 -100.0~100.0%
40.0%
P13.10
Multi-sta
e reference 9 -100.0~100.0%
20.0%
P13.09
Multi-sta
e reference 8 -100.0~100.0%
10.0%
P13.08
Multi-sta
e reference 7 -100.0~100.0%
100.0%
P13.07
Multi-sta
e reference 6 -100.0~100.0%
90.0%
P13.06
Multi-sta
e reference 5 -100.0~100.0%
80.0%
P13.05
Multi-sta
e reference 4 -100.0~100.0%
60.0%
P13.04
Multi-sta
e reference 3 -100.0~100.0%
40.0%
P13.03
Multi-sta
e reference 2 -100.0~100.0%
20.0%
P13.02
Multi-sta
e reference 1 -100.0~100.0%
10.0%
P13.01
Multi-sta
e reference
ro
ert
settin
0~1
0
P13.00
Reserved 0P12.15~P12.27