190
Unit place: PLC running mode selection
0: Stop after single cycle
As shown in Fig. 6-61, the drive will be stop automatically after completing one cycle, and it can start up
only after giving another running command.
Fig. 6-61 Stop mode of PLC after single cycle
1: Hold the end value after single cycle
As shown in Fig. 6-62, the drive will hold the running frequency and direction of the last section
automatically after completing a single cycle.
Fig. 6-62 Retention mode of PLC after single cycle
2: Continuous cycle
As shown in Fig. 6-63, the drive will start next cycle automatically after completing one cycle, and it will
not stop until a stopping command is given.