Fig. 6-65 PLC start mode 2
Hundreds place: Storage selection of PLC status parameter upon power down
0: No storage
The PLC running status will not be saved upon power down, and it will restart from the first section after
power on.
1: Save the stage and frequency at the moment of power down
Record PLC running status upon power-down, including the stage of the power-down moment, running
frequency, and the running time. It shall be continued with the restart mode of interrupted PLC running
defined in the tens places after power-on.
Thousands place: Stage time unit selection
0: s
The running time of each stage will be counted by seconds.
1: min
The running time of each stage will be counted by minutes.
This unit is only valid for PLC running stage time T
1
~T
15
, the acceleration/ deceleration time unit during
PLC operation shall be determined by P11.01.
Note
1. If the running time setting of a certain section of the PLC is zero, this section is disabled.
2. Functions such as pause, disabled, memory status reset can be performed for the PLC process via
terminals, please refer to the function definition of Group P09 terminals.
Sta
g
e 3 runnin
g
time 0.0~6500.0
(
20.0
)
P13.22
Sta
g
e 3 settin
g
0~327H
(
000
)
P13.21
Sta
g
e 2 runnin
g
time 0.0~6500.0
(
20.0
)
P13.20
Sta
g
e 2 settin
g
0~327H
(
000
)
P13.19
Sta
g
e 1 runnin
g
time 0.0~6500.0
(
20.0
)
P13.18
Sta
g
e 1 settin
g
0~327H
(
000
)
P13.17