The values returned in the reading operation are as shown in the following table:   
Register 
address 
Access mode  Value returned  Description 
P01.01 
16-bit  0x1194  The actual value is returned. 
32-bit 0x00001194 
The 16 high bits are filled with 0 and the actual value 
is returned. 
P01.02 
16-bit  0xFE0C 
The 16 low bits are captured and the value retuned is 
-500, which is different from the actual value. 
32-bit  0x0000FE0C  The actual value is returned. 
P01.03 
16-bit  0xFE0C  The actual value is returned. 
32-bit 0xFFFFFE0C 
The 16 high bits are filled with 1 and the actual value 
is returned. 
P01.04 
16-bit 0x1388 
The 16 low bits are captured and the actual value is 
retuned. 
32-bit  0x00001388  The actual value is returned. 
P01.05 
16-bit  0x86A0 
The 16 low bits are captured and the value retuned is 
-31072, which is different from the actual value. 
32-bit 
0x000186A0 
The actual value is returned. 
P01.06 
16-bit  0x 7960 
The 16 low bits are captured and the value retuned is 
31072, which is different from the actual value. 
32-bit  0x FFFE7960  The actual value is returned. 
P01.07 
16-bit 0x FFFF  
32-bit  0x0000FFFF  Parameter of type II, the 16 high bits are filled with 0. 
As shown in the above table, when reading the parameter with an actual length of 32 bits in the 16-bit mode, 
the value returned may not be equal to the actual value. Therefore, please note: the reading operation of the 
16-bit mode is only applicable to parameters with the current value range from -32768 to 32767, and the 
reading operation of other parameters shall adopt the 32-bit mode. 
2. Writing operation   
(1) Command codes 0x06 and 0x41   
Both of these command codes supports changing the single parameter of 16 bits and do not support the 32-bit 
access mode. If the highest bit of the start register address in the request frame is 1, it will return to the 
abnormal information frame, indicating that the address is wrong.   
Note:  
1) The writing operation of the 16-bit mode is only applicable to the parameter of type I with the current value 
range from -32768 to 32767 and the parameter of type II with the current value range from 0 to 0xFFFF.   
2) For the parameter of type I, when these two types of commands are used to write the value of 16 bits into 
the parameter with an actual length of 32 bits, the actual written value is the expanded value. The principles