91
the curve 1
reference
curve 1
reference
P10.19
Actual value
corresponds
to the
inflection
point 1 of
the curve 1
Actual value
of inflection
point 1
The same as P10.15 0.1% 0.0% × √ ○
P10.20
Minimum
reference of
curve 1
Minimum
reference 1
0.0%~P10.18 0.1% 0.0% √ √ ○
P10.21
Actual value
corresponds
to the
minimum
reference of
curve 1
Actual value
corresponds
to minimum
reference 1
The same as P10.15 0.1% 0.0% √ √ ○
P10.22
Types of
analog
output
Types of
analog
output
Unit place of LED: AO1 selection
0: 0~10V(0~20mA)
1: 2~10V(4~20mA)
The current and voltage depend
on the hardware
1 0 √ √ ○
P10.23
Analog
output
terminal
AO1
functions
AO1
functions
0: Output frequency (0~ maximum
frequency)
1: Set frequency (0~ maximum
frequency)
2: Set frequency (after
acceleration/deceleration) (0~
maximum frequency)
3: Motor rotating speed (0~
maximum rotating speed)
4: Output current (0~2*Iei)
5: Output current (0~2*Iem)
6: Output torque (0~3 * Tem)
7: Output torque current
(0~3*Item)
8: Output voltage (0~1.2*Ve)
9: Bus voltage (0~800V)
10: AI1 after adjustment
11: AI2 after adjustment
12: Reserved
13: Output power (0~2*Pe)
14: Percentage of host device
(0~4095)
15: Torque limit value 1
(+10V/+300%)
16: Torque limit value 2
(+10V/+300%)
1 00 √ √ ○