103
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P03.05
Motor power
factor
2003-06h
0.001 to 1.000
Used for calculation of
motor parameters
according to the
nameplate
0.001
Model-de
pendent
×
P03.06
Motor stator
resistance
2003-07h
0.000 to 65.000
0.001
Model-de
pendent
×
P03.07
Motor leakage
inductance
(synchronous
motor axis-D
inductance )
2003-08h
0.0 to 2000.0
0.1
Model-de
pendent
×
P03.08
Motor rotor
resistance
(synchronous
motor back
EMF constant)
2003-09h
0.000 to 65.000
0.001
Model-de
pendent
×
P03.09
Motor mutual
inductance
(synchronous
motor axis-Q
inductance)
2003-0Ah
0.0 to 2000.0
0.1
Model-de
pendent
×
P03.10
Motor no-load
current I0
2003-0Bh
0.1 to 999.9 A
0.1 A
Model-de
pendent
×
P03.11
Motor overload
protection
coefficient
2003-0Ch
20.0% to 110.0%
Set action level (%) =
Rated motor current /
Rated servo drive current
× 100
Actual action level for
low-speed compensation
= Set action level ×
(Output frequency / 30 Hz
0.1%
100.0%
×