P31.03
Berth position of
home searching
Ones: Berth position of home searching
0: Berth at the left of the home
1: Berth at the right of the home
Tens: Installation position of encoder
0: Installed at the motor shaft
1: Installed at the spindle
Hundreds: Reserved
Thousands: Reserved
0000H
×
P31.04
Start setting of
internal positioning
0: Manually set by the DI terminal
1: Auto start
0
×
P31.05
Spindle
transmission ratio
0.000 to 30.000
1.000
×
P31.06
Home searching
speed
0.00 to 30.00
1.00
×
P31.07
Home position
offset
0 to 36000
18000
×
P31.35
Positioning speed
0 to 100.0% (maximum frequency)
20.0
×
Monitoring parameters
Function
code
Name
Value range
Default value
Change
P01.07
Output current
0.0 to 3 Ie
0.0
*
P01.13
Measured frequency of
motor
-650.00 to 650.00 Hz
0.00
*
P01.16
Bus voltage
0 to 800 V
0
*
P01.18
Digital input terminal
state
0 to FFH
0: Off; 1: On
High-speed pulse reference not refreshed
00
*