156
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
fault
P97.20
Running
frequency
upon the third
frequency
2061-15h
0.00 Hz to 3000.00 Hz
0.01 Hz
0.00 Hz
×
*
P97.21
Servo drive
status upon
the third fault
2061-16h
0 to FFFFH
Same as P01.17
1
0000
×
*
P98: Servo drive parameters
P98.00
Serial No.
2062-01h
0 to FFFF
1
500
×
*
P98.01
DSP software
version No.
2062-02h
0.00 to 99.99
0.01
Manufact
urer-
defined
×
*
P98.02
Customized
version No.
2062-03h
0 to 9999
1
Manufact
urer-
defined
×
*
P98.03
FPGA software
version No.
2062-04h
0.00 to 99.99
0.01
Manufact
urer-
defined
×
*
P98.04
Rated capacity
2062-05h
Output power, 0 to 999.9
kVA
(automatically set
according to the model)
0.1 kVA
Manufact
urer-
defined
×
*
P98.05
Rated voltage
2062-06h
0 to 999 V
(automatically set
according to the model)
1 V
Manufact
urer-
defined
×
*
P98.06
Rated current
2062-07h
0 to 999.9 A
(automatically set
according to the model)
0.1 A
Manufact
urer-
defined
×
*
P98.07
Servo drive
selection
2062-08h
0: 220 V
1: 380 V
1
Manufact
urer-
defined
×
*