92
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P00.04
Selection of
key functions
2000-05h
Ones: For manufacturer
commissioning
Tens: Function selection
of the STOP/RESET key
0: The STOP key is valid
only in the keypad control
channel.
1: The STOP key is valid in
all control channels.
Note: The RESET key is
valid in all control
channels.
Hundreds: Function
selection of multi-function
M key
0: No function
1: JOG
2: FWD/REV
3: Command channel
switchover 1 (only valid at
stop)
4: Command channel
switchover 2 (valid at
both stop and running)
5: Keypad lock function
6: Emergency stop
function
7: Coast to stop function
Thousands: Keypad lock
function
0: All locked
1: All locked except the
STOP key
1