Model FV 40.2/4 0.2G
9020132
Turn on the main switch.
Vent the pipes for the chemicals and check for correct dosing.
9.3 Venting (priming) the pipes
Venting of the detergent or rinse pipes must be performed during
commissioning to fill the pipes with detergent and rinse aid.
The pipes must also be vented if the dosing units have sucked in air. This
occurs if a canister is completely emptied during operation, or if one of the
suction lances was not inserted all the way to the bottom of the canister.
For machines with external dosing systems, the detergent and rinse pipes must
be vented in accordance with the manufacturer instructions.
For machines with built-in dosing systems, vent the pipes as follows:
1. Press the STOP key for approx. 5
seconds until CodE 1- - - - - is
displayed.
2. Press the START key 5 times until
1-1 - - - - - is displayed.
3. Press the program key I. 1-2 - - - - -
is displayed.
4. Press the START key. Priming of
the rinse pipe will start. The time
remaining is displayed. By default,
priming takes 180 seconds.
5. If the time has expired and 1-2 - - -
- - is displayed, press program key
I. 1-3 - - - - - is displayed.
6. Press the START key. Priming of
the detergent pipe will start. The
time remaining is displayed. By
default, priming takes 30 seconds.
7. If the time has expired and 1-3 - - -
- - is displayed, press the STOP
key to switch the machine off.