9020132
10.8 Level 2
Switch to level 2 (40044), see page 47.
The parameters relevant for the dosing technology are displayed and can be
changed.
Para.
Definition
Adjustment range / Setting
P104
Dosing quantity for rinse aid
0.101.00 ml/l (0.20 is the default setting)
P105
Dosing quantity for detergent
0.1020.0 ml/l (2.00 is the default setting)
P218
Lack of rinse aid indication
1/0 = Display on/off (Note: must be set
to 0)
P219
Lack of detergent indication
1/0 = Display on/off (1 is the default
setting)
P224
Activation mode for rinse aid
dosing unit
0 = Do not activate (Should only be
selected if not using rinse aid!)
1 = Activate through calculated runtime
(default setting)
Note: settings 2 or 3 must NEVER be
used on this model!
P225
Activation mode for detergent
dosing unit
0 = Do not activate
1 = Activate through calculated runtime
3 = Activate like wash pump (only used
if utilizing an external dispensing
system)
Note: Setting 2 must NEVER be used
on this model!
P321
Capacity of rinse aid dosing unit
0.1010 l/h - Must be set to 1.3 l/h
P322
Capacity of detergent dosing unit
0.1020 l/h - Must be set to 7.0 l/h
P326
Vent (priming) time for rinse pipe
0255 s (180 s is the default setting)
P327
Vent time (priming) for detergent
pipe
0100 s (30 s is the default setting)