Model FV 40.2/4 0.2G
9020132
ERR
Description
Possible cause
Measures/remedy
306
Max. tank level
exceeded. Tank level
analysis disrupted
Air gap dirty
Condensate in level pipe
Level sensor defective
Plug contact not connected
properly
Drain dishwasher
and refill
Call service
technician
307
Tank level sensor
defective
Connector loose
Sensor or I/O circuit board
defective
Call service
technician
310
Short-circuit of
temperature sensor
Sensor defective
Sensor position not correct
Plug contact not connected
properly
Further operation not
possible
Call service
technician
311
Interruption of
temperature sensor
312
Actual tank
temperature too high
(>85°C)
Contactor contact sticking
Incorrect sensor/defective
sensor
Please contact your authorized MEIKO customer service if:
There is an issue with the dishwasher, but no error code is displayed, OR
An error code is displayed that is not listed here, OR
The listed measures cannot solve the problem.
For a list of authorized customer service points, please either scan the QR code
on the back cover of these operating instructions, visit our website at
www.meiko.us or give us a call at (800) 868-3840.
10.6 Modifying the settings
Key
Meaning
Key
Meaning
STOP key
Starts programming
START key
Confirms entry and
jumps to next position
in the code
Program key 1
Increases value by one
Program key 2
Decreases value by
one
1. Press the STOP key for approx. 5
seconds until CodE 1- - - - - is
displayed.