9020132
INFO
Description
Possible cause
Measures/remedy
(P 123) has been
reached
Call service
technician
325
Drain pump active
after triggering of
safety level
Wash tank overfilled
Wait until machine is
drained
420
Lack of rinse aid (with
fill-level detection
integrated)
Canister empty
Suction lance not
inserted correctly
Replace empty
canister
Check suction lance
Vent pipes, if
necessary
520
Lack of detergent (with
fill-level detection
integrated)
ERR
Description
Possible cause
Measures/remedy
001
EEPROM error
EEPROM not
available/defective,
incorrectly plugged in,
incorrect data, empty
Further operation not
possible
Call service
technician
111
Leakage in base drip
tray
Leak in feed hose
Drain hose not connected
correctly to drain
Replace feed hose, if
necessary
Check drain hose
118
Signal of the two door
contact switches not
the same
Malfunction/defect of door
contact switch
201
Boiler level not
reached during first
filling (with pressure
booster pump
integrated)
Fresh water supply not
sufficient (water supply
valve closed)
Feed hose
kinked/loose/leaking
Incoming water strainer dirty
Solenoid valve defective
Boiler switch defective
Check water supply
Check feed hose
Check pre-
filter/strainer and
clean, if necessary
Call service
technician, if
necessary
202
Boiler level not
reached on time
during filling (with
pressure booster
pump integrated)
203
No changed detected
at boiler level switch
when emptying (with
Pressure booster pump
defective
Connections (e.g. pressure
Further operation not
possible