Model FV 40.2/4 0.2G
9020132
Electrical connection, see page 25.
The power supply must be fused in accordance with the regulations and a
lockable main switch provided in the local electrical installation.
The electrical safety of this machine is only ensured if it is connected to a
properly installed protective conductor system. It is very important to verify
this fundamental safety feature. If in doubt, have the building wiring checked
by an electrically skilled person.
Carry out the protective measures as well as the the equipotential bonding
connection in accordance with the regulations of the local power supply
companies as well as the locally applicable regulations.
Fresh water connection
Installation components must be suitable and permitted in accordance with
local regulations.
Turn off the shut-off valve of the fresh water supply line before carrying out
installation work. Check that all lines are securely connected and tight.
When replacing an old machine with a new one, make sure that the existing
feed hose is exchanged for the new feed hose supplied with the machine.
Environment
Do not remove safety and warning notices from the dishwasher and ensure
they are legible. Replace any damaged safety and warning notices.
Do not process hazardous substances (hazardous to health, especially toxic,
highly flammable and explosive substances) in the machine.
Do not operate the dishwasher in a potentially explosive atmosphere.
Maintenance and repair
Observe the maintenance specifications and intervals, including those of
optional bought-in parts.
Only use original spare parts from the manufacturer.
Before opening the housing parts, ensure the local main switch has been
disconnected from power and secured so that it cannot be switched on
again.
Conversions
Installation of an external dosing system is possible. Other modifications to
the machine are not permissible.