5-7
MAINTENANCE MA-5081-E B4 NS ADHESIVE MELTER MANUAL
Only use lubricants recommended by the manufacturer. Other types of
lubricants may cause premature wear or damage the gear.
Approximately 0.10 kg of lubricating grease fits into the gear model used.
Recommended lubricant
Grasa Kluber, Staburags NBU 12/300.
Safety Thermostat
If there is a deactivation of the thermostat, dismantle the tank casing with the
cover and slide the electrical cabinet along. When you can see the thermostat,
press the button indicated to reset it.
Removing the equipment from its base
For more thorough maintenance of the equipment, the melter needs to be
removed from its location so that it can be handled with greater ease and
accessibility.
To do this, remove it from its base as follows:
1. Disconnect the equipment from the mains using the power switch on
the side.
2. For safety reasons, disconnect the supply of compressed air to the
cylinder.
3. Depressurise the system.
4. Disconnect the hoses connected to the distributor outputs both
electrically and hydraulically.
5. Disconnect the input power supply and ground connection.
6. Remove the screws fastening the equipment to the base.
7. Raise the equipment upwards to remove from its base.