3.12 Initial Power On
Each system’s input voltage is specified in the Specifications chapter.
The power cords should be standard 3-wire AC power cords including a safety ground and rated for 15A or higher.
Plug in the first power cable.
Plug in the second power cable.
Wait for the System Status LED to turn green.
Check the System Status LEDs and confirm that all of the LEDs show status lights consistent with normal operation (initially
flashing, and then moving to a steady color) as shown in the figures below. For more information, refer to LED Notifications.
System Status LEDs 5 Minutes After
Power On in SN2700
System Status LEDs 5 Minutes After
Power On in SN2740
System Status LEDs 5 Minutes After
Power On in SN 2410
System Status LEDs 5 Minutes After Power On in SN2100 System Status LEDs 5 Minutes After Power On in SN2010
The system platform will automatically power on when AC power is applied. There is no power system. Check all boards,
power supplies, and fan tray modules for proper insertion before plugging in a power cable.
It may take up to five minutes to turn on the system. If the System Status LED shows red after five minutes, unplug
the system and call your Mellanox representative for assistance.

Table of Contents

Other manuals for Mellanox Technologies Spectrum SN2410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mellanox Technologies Spectrum SN2410 and is the answer not in the manual?

Mellanox Technologies Spectrum SN2410 Specifications

General IconGeneral
BrandMellanox Technologies
ModelSpectrum SN2410
CategorySwitch
LanguageEnglish

Related product manuals