Section 5 - Alert Configuration
90-8M0072763 eng JUNE 2012 Page 37
Type of Alert
Where
Initiated
Why Initiated Message Sent Where Recorded
Low Battery
Clear
TDS
Input battery voltage is greater
than 11.6 V.
No message Alert Log
AWOL
Website
server
Nonreporting for more than 4
hours 5 minutes.
Attention: Mercury TDS
Premium reports the boat has
gone into an AWOL state as of
(date and time)
Alert Log
AWOL Clear
Website
server
Periodic reporting established.
Attention: Mercury TDS
Premium reports the boat has
AWOL state cleared as of
(date and time)
Alert Log
No GPS TDS
Signal strength greater than
9999 for five minutes.
Attention: Mercury TDS
Premium reports a weak or
missing GPS signal and is
unable to establish a Security
Field (date and time)
Alert Log
Note: sends alert every 24
hours until repaired
Poor GPS
Signal
TDS
Signal strength is between 250
and 9999 for five minutes.
Note: dependent on satellite
constellation.
Attention: Mercury TDS
Premium reports a weak or
missing GPS signal and is
unable to establish a Security
Field (date and time)
Alert Log
Diagnostic
Message or
Engine Fault
Code
ECU or
PCM
Trouble codes generated by
engine faults (SmartCraft).
No message Fault Log
TDS Locked TDS
System is reporting Locked or
no valid CAN message has
been received for two minutes.
No message
Boat View page on
website
Security Fence
established (not visible on
website)
TDS Security
Field
TDS
System is reporting Locked
and the vessel has moved
outside of Security Field.
Attention: Mercury TDS
Premium has detected that
your vessel has moved outside
the established security field
on (date and time). Please
view your website for details.
Position Log
Reporting rate changes to
once per minute until alert
is cleared or vessel stops
moving for 15 minutes
TDS Unlocked TDS
System is functional and vessel
operation is normal.
No message
Boat View page on
website
Reporting rate changes to
once per hour if moving
(determined by GPS
position change)
New TDS
Security Field
Established
TDS
System is active and vessel
has moved outside of Security
Fence. TDS recognizes no
change in position for 15
minutes, and a new Security
Fence is established.
No message
(website page under
construction at the time of
this printing)
Reporting rate returns to
once every four hours
unless outside the