8.14.3 EMC areas: first and second environment
Proper installation and wiring of all connecting cables provided, the ARS 2100 SE series servo drives
fulfil the requirements of product standard EN 61800-3. This standard no longer refers to "classes", but
to so-called environments. The first environment includes mains supply networks supplying residential
buildings. The second environment includes mains supply networks exclusively supplying industrial
buildings.
The following applies to ARS 2100 SE servo drives without external filter measures:
Table 44: EMC requirements: First and second environment
EMC type Environment Compliance with EMC
requirements
Interference emission First environment
(domestic environment), C2
Motor cable length up to 25 m
Second environment
(industrial environment), C3
Motor cable length up to 25 m
Interference immunity First environment
(domestic environment)
Independent of motor cable length
Second environment
(industrial environment)
Product Manual „Servo drives ARS 2100 SE“ Version 5.0