Table 15: ARS 2102 SE: Rated current for an ambient temperature of 40 °C
Parameter Values
Power stage clock frequency (kHz)
12
Output current (A
RMS
) 2,5
Max. output current (A
RMS
) 5 7,5 10
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 16
Output current (A
RMS
) 2,2
Max. output current (A
RMS
) 4,4 6,6 8,8
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 19
Output current (A
RMS
) 1,9
Max. output current (A
RMS
) 3,8 5,7 7,6
Max. allowed time (s) 5 1,3 0,5
Table 16: ARS 2105 SE: Rated current for an ambient temperature of 40 °C
Parameter Values
Power stage clock frequency (kHz)
12
Output current (A
RMS
) 5
Max. output current (A
RMS
) 10 15 20
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 16
Output current (A
RMS
) 4,4
Max. output current (A
RMS
) 8,8 13,2 17,6
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 19
Output current (A
RMS
) 3,7
Max. output current (A
RMS
) 7,4 11,1 14,8
Max. allowed time (s) 5 1,3 0,5
Product Manual „Servo drives ARS 2100 SE“ Version 5.0

Table of Contents

Other manuals for Metronix ARS 2102 SE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metronix ARS 2102 SE and is the answer not in the manual?

Metronix ARS 2102 SE Specifications

General IconGeneral
BrandMetronix
ModelARS 2102 SE
CategoryServo Drives
LanguageEnglish

Related product manuals