8.6 Connection: Resolver [X2A]
8.6.1 Device side [X2A]
D-SUB connector, 9-pole, female
8.6.2 Counterplug [X2A]
D-SUB connector, 9-pole, male
Housing for 9-pole D-SUB connector with bolting screws 4/40 UNC
8.6.3 Pin assignment [X2A]
Table 34: Pin assignment: [X2A]
Pin No Denomination Values Specification
1 S2 3,5 V
eff
/ 5-10 kHz
R
i
> 5 k
SINE trace signal, differential
6 S4
2 S1 3,5 V
eff
/ 5-10 kHz
R
i
> 5 k
COSINE trace signal, differential
7 S3
3 AGND 0 V Shield for signal pairs (inner shield)
8 MT- GND (0 V) Reference potential temperature sensor
4 R1 7 V
eff
/ 5-10 kHz
I
A
150 mA
eff
Carrier signal for resolver
9 R2 GND (0 V)
5 MT+
+3,3 V / R
i
= 2 k
Motor temperature sensor, normally closed
contact, PTC, KTY
In addition, a low-impedance connection of the outer cable shield to the housing of the
servo drive has to be established. Therefore, the outer cable shield of the angle
encoder cable must be connected to the housing of the angle encoder connector.
Product Manual „Servo drives ARS 2100 SE“ Version 5.0

Table of Contents

Other manuals for Metronix ARS 2102 SE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metronix ARS 2102 SE and is the answer not in the manual?

Metronix ARS 2102 SE Specifications

General IconGeneral
BrandMetronix
ModelARS 2102 SE
CategoryServo Drives
LanguageEnglish

Related product manuals