Page 42
Table 18: ARS 2108 SE: Rated current for rotated motor (f
el
3 Hz) and for an ambient
temperature of 40 °C
Parameter Values
Power stage clock frequency (kHz)
10
Output current (A
RMS
) 8
Max. output current (A
RMS
) 16 24 32
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 12
Output current (A
RMS
) 7,4
Max. output current (A
RMS
) 14,8 22,2 29,6
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 16
Output current (A
RMS
) 6,3
Max. output current (A
RMS
) 12,6 18,9 25,2
Max. allowed time (s) 5 1,3 0,5
Power stage clock frequency (kHz) 19
Output current (A
RMS
) 5,2
Max. output current (A
RMS
) 10,4 15,6 20,8
Max. allowed time (s) 5 1,3 0,5