Table 8
Parameter Access keys Value range available Key No. times pressed
Pause Time T1 + T2 10 seconds T1 Once
20 seconds (*) T1 Twice
40 seconds T1 Three times
80 seconds T1 Four times
“Pedestrian” command T1 + T2 Opening of 1 leaf to mid-travel T2 Once
Total opening of 1 leaf (*) T2 Twice
Partial opening of 2 leafs to 1/4 of travel T2 Three times
Partial opening of 2 leafs to mid-travel T2 Four times
Motor force T1 + T2 Minimum T3 Once
Medium low (*) T3 Twice
Medium high T3 Three times
Maximum T3 Four times
“Open” command T1 + T2 > Open > Stop > Close > Stop > ... T4 Once
> Open > Stop > Close > Open > ... (*) T4 Twice
> Open > Close > Open > Close > ... T4 Three times
> Open > Open > Open > ... T4 Four times
Pressure discharge
• on Closure (motor 1) T1 + T3 No discharge (*) T1 Once
0.1 s (Minimum) T1 Twice
•• T1 Three times
••• T1 Four times
0.4 s (Medium) T1 Five times
••••• T1 Six times
•••••• T1 Seven times
0.7 s (Maximum) T1 Eight times
• on Opening (motor 1) T1 + T3 No discharge (*) T2 Once
0.1 s (Minimum) T2 Twice
•• T2 Three times
••• T2 Four times
0,4s (medio) T2 Five times
••••• T2 Six times
•••••• T2 Seven times
0.7 s (Maximum) T2 Eight times
• on Closure (motor 2) T1 + T3 No discharge (*) T3 Once
0.1 s (Minimum) T3 Twice
•• T3 Three times
••• T3 Four times
0.4 s (Medium) T3 Five times
••••• T3 Six times
•••••• T3 Seven times
0.7 s (Maximum) T3 Eight times
• on Opening (motor 2) T1 + T3 No discharge (*) T4 Once
0.1 s (Minimum) T4 Twice
•• T4 Three times
••• T4 Four times
0.4 s (Medium) T4 Five times
••••• T4 Six times
•••••• T4 Seven times
0.7 s (Maximum) T4 Eight times
(*) Factory setting
(activated with transmitter
key T1 and “OPEN” terminal
of control unit)
activated with transmitter
key T2)