Appendix A micomTrooper 3 5-50 Watt HF-SSB Backpack Transceiver
143
Note
If a power source failure occurs while the battery is being charged, the FINISH
CHARGE starts flashing, and an alarm tone is heard. To resume charging after
power returns, press again the red CHARGE pushbutton.
7. You will be notified when the battery is fully charged: the FINISH CHARGE indicator will start
flashing and the tone is heard again.
8. At this stage, set the POWER switch to OFF, and remove the battery from the charger.
9. Disconnect the charger power cable from the AC outlet.
Main FLN9541 Technical Specifications
Input voltage 90 to 265 VAC, 20 to 60 Hz
Charged battery voltage 16.8 ±0.2 V
Charging current 3.6 A
Dimensions
220 × 165 × 50 mm
Weight 1.25 kg