Section 8.0 - Electronics Controller Programming
• Programming is quick and simple via the visual LED display.
• Each FUNCTION is clearly shown on the display in text, words, and symbols.
• The VALUE or APPLICATION can easily be adjusted using the buttons on the face of the controller.
• Changed menu values will automatically be saved during the next opening cycle.
SPECIAL WARNING
All Menu Values and Settings must comply with ANSI/BHMA A156.19 Standard
for Power Assist and Low Energy Power Operated Swing Doors.
8.1 Opening Speed (05-12 for Low energy) or (05-20 for Full Automatic)
• This setting is the door "Opening" speed from the fully closed position to the back-check position.
• Use the "UP" and "DOWN" buttons to select the desired door opening speed.
• Active the door to check the speed is correctly adjusted.
8.2 Back-check Speed (01-05)
• This setting is speed when the door reaches the back-check position to the full door opening.
• Use the "UP" and "DOWN" buttons to select the desired door back-check speed.
• Activate the door to check the speed is correctly adjusted.
8.3 Safety Speed (Hold/Crawl)
• This setting is door speed when "Safety 2" is active during the opening cycle.
• Use the "UP" and "DOWN" buttons to select either Hold or Crawl speed.
8.4 Closing Speed (01-15
• This setting is the door "closing" speed from the fully opened position to the Latch area.
• Use the "UP" and "DOWN" buttons to select the desired door "Closing" speed.
• Activate the door to check the speed is correctly adjusted.
8.5 Latch Speed (01-05)
• This setting is the door "Closing" speed in the Latch area until fully Closed.
• Use the "UP" and "DOWN buttons to select the desired door "Latching" speed.
• Activate the door to check the speed is correctly adjusted.