Basic Settings Table describing the Controls Functions, Settings, Values and
Defaults
All values and settings must comply with ANSI/BHMA A156.19 Standard for Power Assist and Low Energy Power
Operated Swing Doors.
OPENING SPEED
Door opening speed from full closed to back
check position
5 sec = slowest
20 sec = fastest
BACK CHECK SPEED
Door speed at final section of opening
1 sec = slowest
5 sec = fastest
SAFETY SPEED
Slow speed (crawl) or stop (hold) when
Safety1 is active
CLOSING SPEED
Door closing speed from full open to latch
position
1 sec = slowest
15 sec = fastest
LATCH SPEED
Door speed at final section of closing
1 sec = slowest
5 sec = fastest
CURRENT LIMIT
Obstruction detection
1 sec = more sensitive
20 sec = less sensitive
ACTIVATION TIME
Time begins at activation signal ON
1 sec = minimum
60 sec = maximum
HOLD ON MANUAL OPEN
Door held open when pushed by hand. Not
active with push & go
A = No
B = 5 steps (1-5 sec)
ELECTRIC DOOR STOP
Setting stop position by encoder
E-LOCK
Strike or Electromagnetic Lock
E-LOCK DELAY
Time before E-Lock will release
18 steps:
0.2 sec to 2.0 sec
0.2 sec = minimum
2.0 sec = maximum
LATCH POSITION
Position at which final section of closing begins
2% = minimum
30% = maximum
BACK CHECK POSITION
Position at which final section of opening
begins
70% = maximum
98% = minimum
PUSH & GO ACTIVE TIME
Time door is pushed open before activation
1 sec = minimum
30 sec = maximum