8.13 Back-check Position (70%-98%)
This setting is to adjust the door Back-check position of the Opening cycle.
Use the "UP" and "DOWN" buttons to set the starting point for the Back-check position.
Activate the door. During the Opening cycle, check the position where the Back-check begins and the door
starts to slow down.
Check this setting is correctly adjusted.
In windy conditions, set to 70%.
8.14 Push & Go (Yes/No)
This setting is to Enable or Disable the Push & Go feature, also known as Manual Activation, when the door is
Manually pushed or pulled open by hand.
Caution: Do not activate this feature without training and specifically requested by the end user.
Use the "UP" and "DOWN" buttons to Disable or Enable this feature.
8.15 Push & Go Active Time (01-30 seconds)
This setting is to adjust the duration of the door Open cycle in seconds from when the door is Manually pushed
Open to when the Push & Go feature is enabled.
Use the "UP" and "DOWN" buttons to select the desired Opening time.
8.16 Power Close (Yes/No)
WARNING: You should always install a Presence Safety sensor when Enabling this feature.
This setting is to Enable or Disable the Power Close Assist feature.
When Power Close is "ON", should the door reach the Latch position and cannot fully Close after 3 seconds,
the motor will assist the spring in order to fully Close the door.
This feature is used when the pressures on the door prevent the door from fully Closing
Use the "UP" and "DOWN" buttons to Enable or Disable this feature.
8.17 Power Close Force (01-05)
This setting will allow you to increase or decrease the amount of Closing Force needed to fully Close the door
at the Latch position.
This feature is used to counter act Stack or Wind pressures.
IMPORTANT: When using the Power Close Force feature, we strongly recommend to wire a Presence Safety
sensor into the input (PC Cancel" on the control board terminal that Cancels out this feature when a pedestrian
presence is detected. PC = Power Close.
Use the "UP" and "DOWN" buttons to select the desired Closing Force. Use the lowest Force setting needed to
ensure positive Latching in these conditions.
Check this setting is correctly adjusted.
8.18 Door Seal (Yes/No) Not an Active Function.