EasyManua.ls Logo

MICRO-EPSILON IF2030/ENETIP - Page 26

MICRO-EPSILON IF2030/ENETIP
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 26
Commissioning
IF2030/ENETIP
Class Instance Attribute Data type Name RS485 RS422 Description
0x0413
String Parameter Read or write string parameter
0 Uint8 NrOfObjects
1 Uint16 RW Parameter ID
Please refer to the sensor documentation for
available parameter IDs and their types
2 Uint8 RW Reserved
3 Uint8[246] RW Value Value
4 Uint8[14] R Name Designation
0x0430 RS422 ASCII
Access
RS422 commando
1 Uint8[128] RW Send Cmd
Buffer for a 128-character ASCII command,
termination with ‘\n’ or 0x0A
2 Uint8[896] R Cmd Answer
Answer from sensor without shortening, e.g.,
Line feed; if buffer overflows, e.g., PRINT ALL,
answer is truncated