41
SYMPTOM POSSIBLE CAUSE POSSIBLE SOLUTION
Loses pressure in
MANUAL
Pump Air-lock• Clean strainer•
Larger hoses•
Little or no pressure
adjustment in MANUAL
Too much restriction in servo loop• Largerhosesandttings•
No sharp bends•
Pressure won’t go high
enough in MANUAL
Pump starved or too small•
Too much agitation•
Throttle, range adjust or pressure relief valves•
Larger hoses•
Reduce agitation•
Adjust•
Pressure, Speed and
Spray Rate don’t check
out according to charts
Inaccurate pressure reading•
Dirty or worn tips•
Use a different gauge and check •
each boom.
Clean or place•
Pressure always goes
too high in AUTO
Minimumowratetoohigh•
Inline/Bypass setting•
Re-calibrate•
Set appropriately•
Pressureuctuates
greatly in AUTO
Sagging or kinked hoses•
Throttle valve too far closed•
Pump starved or too small•
Valve response speed set too high (“Special” Cal)•
Support or replace hoses•
Adjust throttle and range valves•
Larger hoses•
Larger pump•
Clean strainer•
Reduce valve speed setting•
Troubleshooting (cont)
Plumbing Troubleshooting Chart