IMPORTANT INFORMATION AND SAFETY INSTRUCTIONS
Installers should be qualified electricians or technicians.
The installation information in the manual is for information purposes only.
The monitoring and operation information in this manual is intended for anyone who needs to
operate the MPPT.
The MPPT input cannot be paralleled with another PV array.
Read the instructions carefully before installing and operating the MPPT.
MPPT connection and installation instructions must be followed.
The unit should only be opened by skilled personal.
Keep the MPPT clean and dry.
The MPPT will not operate without batteries connected to the MPPT.
The MPPT should be installed indoors, in a ventilated and dry area.
Mount the MPPT vertically.
Do not install the MPPT on a rugged or inclined surface.
Do not install the MPPT near water or in damp environments.
Do not install the MPPT where it would be exposed to direct sunlight.
Do not remove the MPPT casing.
Keep the MPPT away from heat emitting sources.
Do not block the MPPT ventilation openings.
Do not leave objects on top of the MPPT
Do not expose the MPPT to corrosive gasses.
Install the MPPT away from any explosive gasses.
Ambient temperature: 0°C 40°C.
Use panels of the same type and size in an array.
Sketches are intended for illustrative purposes only and are not intended to provide an
electrical design.
Damage caused by reverse polarity is not covered by warranty.
Do not exceed the MPPT 150 Volt maximum input voltage (Voc) rating.
Refer to your solar module documentation for the worst-case (coldest) module temperature
voltage, it should provide the Voc vs. temperature data.
Contact the battery manufacturer or supplier for the correct charging specifications.
Incorrect charging can damage or destroy batteries.
PLEASE BE AWARE:
WARRANTY WILL BE NULL AND VOID IF PANEL
SURGE PROTECTION IS NOT INSTALLED WITH
ALL LCD MPPT INSTALLATIONS
WARNING
High DC voltage present and is capable of causing severe injury.
.