EasyManua.ls Logo

Microsemi ATS-6501B T-Flex - Real Time Data Logging

Microsemi ATS-6501B T-Flex
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC 6501_Release V
ATS-6501 Users Guide
80
[rxhwlevelsa] ontime 60
[waas9a] onchanged
[OK] 2013-08-07T20:56:49Z
Once the desired changes are made save the set up using the save_logs ftp command.
ATS 6501>save_logs ftp
[OK] 2010-05-25T19:07:37Z
Note: If you do not save the setup the system will come back up with the factory defaults when
the system is rebooted, restarted, or power cycled and any changes that were made will not be
retained. Users can also save these settings to a different configuration file if desired by adding
the filename to the save_logs ftp command.
3.7.2 Real Time Data Logging
For this purpose, Port 1135 may be configured to provide real-time gps log output. Which logs
are output will be specific to the application but users may request any of the ASCII logs
specified in the user manual for the Novatel OEMV receiver
http://www.novatel.com/support/docupdates.htm#oemv
To set up the real time data logging users will need to follow the steps outlined below to set up
the type of data to be logged and then turn the logging on. Users can also verify the data logging
configuration settings.
A. Telnet into the command port (1700).
B. Use the log rt <novalog> command to set up they data type to be sent over the data port.
The novalog text on the command line specifies which data type to forward over this
port. Some examples are provided below.
ATS-6501>log rt timea ontime 1
ionutca onchanged // log IONO & UTC data
rawalma onchanged // log almanac on startup
rangea ontime 60 // L1/L2 observations @ 60 seconds
ionutca ontime 7200 // log IONO & UTC data every 2 hours
rawephema onchanged // log broadcast ephemerides
waas9a onchanged // log WAAS data
C. If needed, turn the real time logging on using the log_enable rt command.
ATS-6501>log_enable rt 1
[OK] 2013-08-08T13:55:49Z
D. You can verify the real time log settings using the settings gps_logging:rt command.
ATS 6501>>settings gps_logging:rt
[enable] true
[log_selection]
[gpggartk] ontime 1
[ptds] ontime 20
[rangea] ontime 30
[timea] ontime 1

Table of Contents