P-76 reading
this is one of the optional displays selected in the display options
parameter, P-39, and may also be obtained by pressing .
This reading incorporates both the measurement and display offsets.
MODE READING
(P-2) (linear, %, volume)
material material
space space
DLD differential
vol. tot. material
OCM head
P-77 liquid level
this is the actual liquid level referenced to zero or empty level in m, cm,
ft or in.
P-78 space or distance
this is the actual distance from the transducer face to the liquid level in
m, cm, ft or in.
Parameters P-79 through P-88 are used for echo processing and analysis.
P-79 scope display
LCD display
window
marker
Curve - TVT
Profile
select any combination of scope displays
0 = scope display off (display ‘_’) (F=_ _ _ _)
1 = scope display on (display‘
u
’, n, C or P)
press
e.g. to display the marker and the curve on the oscilloscope :
press , enter “0011"
press ,display will show _ _CP
ALT
DISP
ENTER
ENTER
u
n C P
∗
SD
CI
OS
PP
EL
A
Y
S
PL-399 7 – 17