4
SECTION 2
English Units
Table 1: Capacity / Pressure Table (continued)
0 to 9.2 GPH - 3000 psi maximum
SERIES
GEAR
RATIO
CODE
STROKES
PER MINUTE
METALLIC LIQUID ENDS
GPH AT 2000 PSI GPH AT 2500 PSI GPH AT 3000 PSI
60HZ 50HZ 60HZ 50HZ 60HZ 50HZ 60HZ 50HZ
mRoy
XT
11/32”
(9 mm)
Plunger
77 23 19 0.27 0.23 0.26 0.21 0.24 0.20
Requires
1/2 HP
minimum
48 37 30 0.44 0.37 0.41 0.34 0.38 0.32
24 73 60 0.87 0.73 0.80 0.67 0.74 0.62
15 117 96 1.37 1.14 1.27 1.06 1.19 0.99
10 185 152 2.2 1.8 2.1 1.7 1.9 1.6
mRoy
XW
1/2”
(13 mm)
Plunger
38 48 40 2.8 2.3 2.6 2.2 2.5 2.1 Requires
1 HP
minimum
25 72 60 4.3 3.6 4.0 3.3 3.8 3.1
19 96 80 5.8 4.8 5.4 4.5 5.0 4.2
12 144 120 9.2 7.7 8.6 7.2 8.0 6.7
Requires
1 1/2 HP
minimum