- 5.17 -
Sleep cleaning [SLEEP clean]
To prevent clogging while the power switch has been turned off, ink is ejected from the
head at regular intervals.
The head itself must be cleaned also at regular intervals which are set as shown below.
STEPS:
1. Select the [SLEEPclean].
page 5.2.
2. Press the [ENTER] key.
3. Press the Jog key [
] or [ ] as needed to
select the interval.
4h, 8h, 12h, 24h, OFF
4. Press the [ENTER] key.
[SLEEPclean] is displayed.
5. Press the [END] key twice.
The menu return to the LOCAL mode.
MAINTENANCE
SLEEPclean < ent >
SLEEPclean
INTERVAL = 8h
SLEEPclean
INTERVAL = 12h
MAINTENANCE
SLEEPclean < ent >
< LOCAL >
TWICE