- 3.8 -
Cleaning the nozzle [NOZZLE WASH]
If nozzle clogging cannot be resolved even after cleaning several times,
execute the [FILL UP INK] and [HEAD WASH] functions.
page 5.18, 19
If this error cannot be resolved with these functions, contact your dealer.
If there exist cartridges with [NEAR END] and/or [INKEND], the cleaning
function (suctioning through nozzles) is not activated. Replace cartridges
with [NEAR END] and/or [INK END], before cleaning.
STEPS:
1. Press the [FUNCTION] key in the LOCAL mode.
2. Press the Jog key [
] or [ ] to select the
[MAINTENANCE].
3. Press the [ENTER] key.
[STATION] is displayed.
4. Press the [ENTER] key.
[CARRIAGEout] is displayed.
5. Press the Jog key [ ] or [ ] to select the
[NOZZLE WASH].
6. Press the [ENTER] key.
Move the carriage on the platen.
7. Open the front cover.
8. Holding the projections at both ends, draw out
the wiper.
9. Remove the ink at the wiper and the bracket
using a swab dampened with cleaning fluid RS.
If dirt of curl is serious, replace the wiper with a
new one. At the time of replacement, be sure to
terminate the plotter operation and follow the
wiper replacement procedure.
page 5.5
FUNCTION
SET UP < ENT >
FUNCTION
MAINTENANCE < ENT >
MAINTENANCE
STATION < ent >
STATION
MENT : CARRIAGEout
STATION
MENT : NOZZLE WASH
Wiper Cleaning
COMPLETED :ent