2. Daily Maintenance
8
2
Select [Station] > [Carriage Out] > [Move To Platen Right End], then press the [ENTER] key.
• The carriage moves on the platen.
3
Open the front cover.
4
Clean the cap rubber.
• Wipe off any ink adhering to the cap rubber using a cleaning stick moistened with washing liquid.
• Wipe off the washing liquid. Make sure none remains.
Cap rubber
5
Check to confirm that the cap slider is not tilted once cleaning is complete.
• If the cap slider is tilted, move the slider block to the left or right to correct the tilt.
6
Press the [ENTER] key once cleaning is complete.
7
Close the front cover, then press the [ENTER] key.
NCU Cleaning
The NCU uses a sensor to monitor the ink droplets ejected from the print head nozzles. Continuing to use
the product when it is dirty may prevent the nozzle recovery function from operating correctly.
• Be careful to avoid leaving fragments from the cleaning stick behind when cleaning. These
fragments will increase the risk of print defects (e.g., nozzle clogging, deflection).