20 Calibration
MINIMUM SPEED (MIN SPD)
The MIN SPD setting determines the motor speed when the speed
adjust potentiometer is turned full CCW. It is factory set for zero
speed.
To calibrate, set the MIN SPD trimpot full CCW. Turn the speed
adjust potentiometer full CCW. Adjust the MIN SPD trimpot until
the desired minimum motor speed is reached.
MAXIMUM SPEED (MAX SPD)
The MAX SPD setting determines the motor speed when the
speed adjust potentiometer is turned full CW. It is factory set for
maximum rated speed.
To calibrate, set the MAX SPD trimpot full CCW. Turn the speed
adjust potentiometer full CW. Adjust the MAX SPD trimpot until
the desired maximum motor speed is reached.