◆ The two pointers on the analog
scale L indicate the brightness
of the main light source and the
brightness of the fill light source.
● Read the difference in exposure
of the two values.
● The reading accuracy of the
analog scale L is 0.5 stops.
Special FunctionsSpecial Functions
5
Press the incident light
measuring button while
holding the meter near the
subject with the Flat
Diffuser facing the main
light source.
6
Press the MEMORY button
to store the measurement
value.
7
Press the incident light
measuring button while
holding the meter near the
subject with the Flat
Diffuser facing the fill light
source.
● Block out all light from the main
light source with your hands or
other means, so that it does not
directly fall on the Flat Diffuser,
or if possible, turn off the main
light source.