Specifications
Display range Exposure: F1.0 to 128+0.9 stop
(0.1 stop increments)
EV: -17 to 40.9 (0.1 stop increments)
Shutter speed (ambient): 30 min. to 1/16000 sec.
(1, 1/2, 1/3 stop increments)
Shutter speed (flash): 30 min. to 1/1000 sec.
(1, 1/2, 1/3 stop increments)
Frame rate (Opening angle of 180°):
8, 12, 16, 18, 24, 25, 30, 32, 64, 128
ISO: 3 to 8000 (1/3 increments)
Exposure difference: -10 to +10
(0.1 stop increments)
Analog scale: FNO. 1.0 to 90
(1/2 stop increments)
Analyze scale: Flash light proportion 0 to 100%
(25% increments)
Other functions Latitude display function, Light Ratio Analyze
function, Memory function (10 measured values),
S/A/H calculation, Brightness difference function,
Exposure correction function: -10 to +10 (0.1 stop
increments)
Others Sync terminal
Power One AA alkaline dry cell (LR-6/1.5 V)
Battery life Approx. 30 hours: (Continuous operation for
ambient light/incident light measurement, with
alkaline dry cell)
Operating -10°C to 50°C ( 14°F to 122°F)
temperature/humidity Relative humidity 85% max. [at 35°C (95°F)],
range no condensation
Storage -20°C to 55°C (-4°F to 131°F)
temperature/humidity Relative humidity 85% max. [at 35°C (95°F)],
range no condensation
Dimensions 63 (W) x 175 (H) x 30 (D) mm
Weight 170 g (excluding battery)
Standard accessories Spherical Diffuser, strap, case
*Optional accessories Flat Diffuser, Sync. Cord III
Specifications and external appearances described herein are subject to
change without notice.
Type Hand-held exposure meter for measuring ambient
and flash light
Reception method Incident-light and spot reflected-light readings
Receptors Incident-light readings: Spherical Diffuser, Flat
Diffuser, Swivels 270°
Spot reflected-light: angle 1°
Receptor element Silicon photocell
Measuring modes AMBI mode: Ambient light
CORD mode: Flash light using a sync cord
NON CORD mode: Flash light without a sync cord
(for incident-light reading only)
Measuring range (ISO100)
Ambient light Incident-light readings:
EV-2.0 to 19.9
Spot reflected-light: Ev2.0 to 24.5
Flash light Incident-light readings:
FNO. 1.0 to 128+0.9 stop
Spot reflected-light:
FNO. 2.8 to 128+0.9 stop
Measuring distance 1.3 m to infinity () (for spot measurement)
Viewfinder Single-lens reflect type with fixed focal point
Magnification: 1.2x
Viewing angle: 12° (vertical) x 17° (horizontal)
Dioptric adjustment range: -3.0 to +1.0
Repeatability ±0.1 EV
Calibration coefficient Incident-light readings: C=330 (Spherical Diffuser)
C=250 (Flat Diffuser)
Spot reflected-light: K=14
Specifications
flashmetervieng.qx3302.12.259:21PMページ78

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minolta FLASH METER VI and is the answer not in the manual?

Minolta FLASH METER VI Specifications

General IconGeneral
BrandMinolta
ModelFLASH METER VI
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals