1 PREPARATION
1.3 Required Products
10
1
1.3
Required Products
This manual describes the procedures required for the communications between FX5 CPU modules and servo amplifiers,
using a system configuration example where one FX5S CPU module is connected to two servo amplifiers (MR-JET-G).
*1 For applicable servo motors, refer to the following.
MR-JET User's Manual (Hardware) [1.2 Servo amplifier/motor combinations]
Software
GX Works3 must import the following.
*1 The file before decompression (such as *.zip) can also be imported.
FX5S CPU module 1 MR-JET-G 2, Servo motor 2
The FX5S CPU module supports the communications from the first released
product.
Use the MR-JET-G satisfying the following.
• Firmware version: C5 or later
Select applicable servo motors.
*1
Personal computer and software Ethernet cable 3
GX Works3
• Applicable software version: 1.080J or later
MR Configurator2
• Applicable software version: 1.125F or later
Use Ethernet cables compliant with the following standards.
• Category 5 or higher, straight cable (double shielded / STP)
• IEEE 802.3 (100BASE-TX)
• ANSI/TIA/EIA-568-B (Category 5)
Item File name Reference
FB library MotionControl_CCLinkIEFBasic_F.mslm Page 19 PROGRAMMABLE CONTROLLER SETTINGS
Profile 0x0002_MR-JET-G(E_CCIEFBasic)_1_en.cspp
*1
Page 59 Downloading and Registering a Profile
First
servo amplifier
(Station number 1)
Second
servo amplifier
(Station number 2)
Servo motor