3 PROGRAMMABLE CONTROLLER SETTINGS
3.4 Communication Settings of GX Works3
24
3
5.
Select [No Specification] of "Target Station", and then click [Communication Test]. When the connection has succeeded,
click [OK].
Precautions
When the communications test detects a connection failure, perform the following.
Check the power supplies of the programmable controller and the servo amplifiers, wiring with Ethernet cables.
Check the IP address and the subnet mask of the personal computer.
Initialize the programmable controller.
For how to initialize the programmable controller, refer to the following.
GX Works3 Operating Manual [18.6 Initializing/Clearing a Memory]