3 PROGRAMMABLE CONTROLLER SETTINGS
3.5 Parameter Settings
When the following window appears, click [Yes].
6.
Next, set parameters to automatically perform data transfer between link devices of the servo amplifiers and devices of
the programmable controller. Double-click "Detailed Setting" of "Refresh Settings".
7.
Select "Specify Device" for the refresh targets on the CPU module side, and set the names and start addresses of the
devices to be assigned to the link devices. After the setting, click [Apply]. In this manual, the following setting values are
used.
Device name of the link side Target Device Name Start
RX Specify Device B 00000
RY Specify Device B 00080
RWr Specify Device W 00000
RWw Specify Device W 00040
Double-click