1 FUNCTIONS
1.1 EtherNet/IP Communication Functions
17
1
Applied connection of EtherNet/IP communications
When the RJ71EIP91 is the target
*1 A method to send data when the status changes. On the RJ71EIP91, data is sent when Application Trigger is requested.
*2 A method for communicating with a fixed size.
*3 A method for communicating with a variable size.
*4 A connection set from the RJ71EIP91 to the originator only for receiving data.
When the RJ71EIP91 is the originator
*1 A method to send data when the status changes. On the RJ71EIP91, data is sent when Application Trigger is requested.
*2 A method for communicating with a fixed size.
*3 A method for communicating with a variable size.
*4 A connection simultaneously set from the RJ71EIP91 to the target for sending data and set from the target to the RJ71EIP91 for
receiving data.
*5 A connection set from the target to the RJ71EIP91 only for receiving data.
*6 A connection that monitors the data communication with the target to which a connection has been established.
*7 Connection requests can be set, but are sent from the RJ71EIP91 with a fixed size.
For the connection setting method, refer to the following.
Page 79 [Connections] tab
: Requests can be accepted from the EtherNet/IP device, : Requests cannot be accepted from EtherNet/IP device, : No combination
EtherNet/IP
communications
Connection settings
Connection
type
Trigger type Input type
(target to originator)
Output type
(originator to target)
Cyclic Application
Trigger
Change
of
State
*1
Fixed
*2
Variable
*3
Fixed
*2
Variable
*3
Class1 tag
communications
Input Only
*4

Class3 message
communications

UCMM message
communications

: Requests can be sent to the EtherNet/IP device, : Requests cannot be sent to EtherNet/IP device, : No combination
EtherNet/IP
communications
Connection setting
Connection
type
Trigger type Input type
(target to originator)
Output type
(originator to target)
Cyclic Application
Trigger
Change
of
State
*1
Fixed
*2
Variable
*3
Fixed
*2
Variable
*3
Class1 instance
communications
Exclusive
Owner
*4

*7
Input Only
*5

*7
Listen Only
*6

*7
Class1 tag
communications
Input Only
*5

*7
Class3 message
communications

UCMM message
communications
