3 EtherNet/IP Configuration Tool
3.1 Window Structure
Setting window on the Consumer Tag side
Select "Target (Class1 Tag)" in the network configuration settings. Ö [Device] Ö [Properties]
*1 Characters from A to Z, numbers from 0 to 9, "." (dot), "-" (hyphen), and "_" (underscore) can be used. For the first character of a name,
only characters from A to Z can be used.
*2 Only even numbers can be set.
Item Description Setting range
Device Designation Device Name Sets the name to use in management with EtherNet/IP
Configuration Tool.
By default, names of EtherNet/IP devices not registered in the
network configuration setting are displayed in the form such as
"DEVICE-A" and "DEVICE-B".
Up to 50 characters
*1
(Default: Refer to the left.)
Number Sets the control number of the EtherNet/IP device.
The control number that has not been set for EtherNet/IP devices
can be selected from the list.
000 to 255
(Default: Minimum value of the
control numbers of EtherNet/IP
devices that have not been
set)
Active Configuration Enables or disables the parameters set for the EtherNet/IP device
on the RJ71EIP91.
Selected: Enabled
Not selected: Disabled
Disable this item when the parameters of the EtherNet/IP device
need to be deleted from the RJ71EIP91 with the settings in
EtherNet/IP Configuration Tool held.
Clearing of this check box is reflected against 'Reserved station
(Class1)' (Un\G27168 to Un\G27183) on the RJ71EIP91.
•Selected
Not selected
(Default: Selected)
Comment Displays the comment input field. Up to 255 single-byte
characters
(Default: Blank)
Connection No Displays the connection number of the EtherNet/IP device.
Connection numbers of EtherNet/IP devices are assigned from 1
in the order in which they were added.
Producer Tag Tag Name Specifies the tag name used in Class1 tag communications. Up to 255 single-byte
characters
(Default: Blank)
Size Specifies the data size used in Class1 tag communications. (Unit:
Bytes)
2 to 1444
*2
(Default: 2)