6 PARAMETER SETTING
6.1 CC-Link IE Field Network Parameter Setting
43
6
6 PARAMETER SETTING
This chapter describes the procedure for setting parameters of the IO-Link module.
6.1 CC-Link IE Field Network Parameter Setting
Set the parameter of the IO-Link module with the network parameter written to the CPU module of the CC-Link IE Field
Network master station. For details on setting the CC-Link IE Field Network master station, refer to the following.
User's manual for the master/local module used
Operating procedure
1. Open the "CC IE Field Configuration" window.
[Navigation window] [Parameter] [Module Information] [RJ71GF11-T2] [Basic Settings] [Network
Configuration Settings]
2. Select an IO-Link module from "Module List", and drag and drop it to the list of stations or the network map.
3. Configure the IO-Link module settings.
4. Close the "CC IE Field Configuration" window.
[CC IE Field Configuration] [Close with Reflecting the Setting]
(1) List of stations
(2) Network map
Item Description
STA# Set the station number of a slave station to be connected to the network.
The station number need not be a serial number. (Must not be overlapped.)
Station Type Automatically set to "Intelligent Device Station".
RX/RY Setting Set RX and RY assignment. Automatically set to 48 points for the IO-Link
module.
RWw/RWr Setting Set RWw and RWr assignments. Automatically set to 132 points for the IO-
Link module.
Reserved/Error Invalid Station/System Switching Monitoring Target Station Use this to set the slave station as an error invalid station or a switching
monitoring target station.