EasyManua.ls Logo

Mitsubishi CR760-Q - Page 46

Mitsubishi CR760-Q
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-35
Error no. L3280
1Error list
L3280 Error message Cannot execute without GetM
Cause The command you attempted to execute cannot be executed without GetM. Or, a non-existing mechanical
number was specified.
Measures Execute it after executing the RelM and GetM commands in another task slot.
L3281 Error message Cannot execute during RUN
Cause Cannot execute during operation.
Measures Cannot execute during operation.
L3282 Error message "Can't RUN (not select, attribute)"
Cause The program is not selected or the attribute is illegal.
Measures Load the program into the specified task slot. Or, change the program attributes.
L3285 Error message Cannot execute (RUN or WAI)
Cause can't execute in the state of stopping or executing.
Measures Reset the program (cancel the abort status).
L3286 Error message Program is empty
Cause Execution of an empty program was attempted.
Measures Make the program or select the correct program.
L3287 Error message Cannot execute (ERROR ALWAYS)
Cause This command cannot be used when the start conditions are ERROR and ALWAYS.
Measures Correct the program.
L3288 Error message Cannot execute while editing
Cause That program cannot be executed because it is being edited.
Measures Finish editing the program first, and then start it.
L3289 Error message Program does not exist (SLT*)
Cause The program designated in the slot table does not exist.
Measures Correct the slot parameter.
L3290 Error message System slot cannot be executed
Cause The system slot cannot be executed.
Measures Check whether another slot (user slot) is being operated.
L3300 Error message User slot cannot be executed
Cause A user slot cannot be executed.
Measures Check whether the system slot is being operated.
L3310 Error message Cannot execute XRun (Runing)
Cause XRun is not possible as the designated slot is operating.
Measures Stop the specification slot, and execute.
L3320 Error message Cannnot execute XRun (empty)
Cause XRun is not possible as the program has not been selected.
Measures Specify program name to the argument or execute XLoad.
L3330 Error message Cannnot execute XStp (empty)
Cause XStp is not possible as the program has not been selected.
Measures correct the program, and execute.
L3340 Error message Cannnot execute XRst (empty)
Cause XRst is not possible as the program has not been selected.
Measures Resetting is possible in the state of waiting only.
L3350 Error message Cannnot execute XRst (Running)
Cause Xrst is not possible as the program is executing.
Measures Stop execution, and do it.
L3360 Error message Cannnot execute XLoad (not PSA)
Cause XLoad cannot be executed when the program cannot be selected.
Measures Execute XRst, and do it.
Error No. Error cause and measures