Error no. H7820
1-52
H7820 Error message Mxt Scommand timeout
Cause The setting time of the MXTTOUT parameter has been exceeded.
Measures Make the MXTTOUT parameter value larger.
H7830 Error message "Ethernet card is not installed, or command disable"
Cause Ethernet card is not installed, or command disable.
Measures Install Ethernet interface card.
H7840 Error message Mxt command Illegal received data
Cause The command argument and the data type do not match.
Measures Check the command and the data you are sending.
L8300 Error message There are a lot of GETPOS define
Cause GETPOS function are up to 8.
Measures Please use the same Act No. or reset an unnecessary program.
L8310 Error message GETPOS undefined
Cause GETPOS undefined.
Measures Please define GETPOS.
H8320 Error message System Error (GETPOS)
Cause Internal data of GETPOS is illegal.
Measures Turn the power OFF and ON once.
H8400 Error message CTN data is illegal (Prec)
Cause CTN data is illegal. It changed to Prec Off.
Measures Try to set be a Prec mode again.
L8600 Error message The vision is a unconnection
Cause The vision is a unconnection
Measures Please check Com No. and Parameter
L8601 Error message The vision can't be logged on
Cause The parameter of the user-name or the password is abnormal
Measures Please set the parameter correctly
L8602 Error message Password is abnormal
Cause The password of the user-name is not corresponding
Measures Please set the password correctly
L8603 Error message Parameter is abnormal
Cause The parameter of the user-name or the password is abnormal
Measures Please set the parameter correctly
L8610 Error message The communication is abnormal
Cause The communication was cut
Measures Please check the communications cable
L8620 Error message The vision number is abnormal
Cause The number is not designated by NVOpen
Measures Please check NVOpen command
L8621 Error message Vision program name is abnormal
Cause The vision program name has exceeded 15 characters
Measures Please make the program name within 15 characters
L8622 Error message There is no vision program
Cause There is no specified vision program
Measures Please check the vision program name
L8623 Error message SKIP number is already used
Cause SKIP number is already used
Measures Please confirm the SKIP number