13 Example of Communication between Master Station
13.2 When Remote Net Ver. 2 Mode is Used
159
FX3U-16CCL-M User's Manual
11
Programming
12
Remote I/O
Communication
Example
13
Remote Device
Communication
Example
14
Int. Device
Communication
Example
15
Compound Sys.
Communication
Example
16
Troubleshooting
A
Version
Information
B
Setting Sheet
C
Differences with
FX
2N
-16CCL-M
- Remote register (RWw, RWr)
Master station
Ver. 2 compatible
Remote device station
(Station No. 4)
AJ65VBTCU-68DAVN
RWw 0
RWw 1
RWw 2
RWw 3
RWw 5
RWw 6
RWw 7
RWw 8
RWw 9
Remote register (RWw)
For station
No. 1
For station
No. 4
BFM No.
PLC
TO
instruction
D100
RWw 4
Remote register (RWw)
CH.1 digital value setting
CH.2 digital value setting
D101
RWw A
RWw B
CH.1 digital value setting
CH.2 digital value setting
CH.4 digital value setting
CH.5 digital value setting
CH.6 digital value setting
CH.7 digital value setting
CH.8 digital value setting
CH.3 digital value setting
D102
D103
D104
D105
D106
D107
D108
D109
D110
D111
D112
D113
D114
D115
D116
D117
D118
D119
CH.3 digital value setting
CH.4 digital value setting
CH.5 digital value setting
CH.6 digital value setting
CH.7 digital value setting
CH.8 digital value setting
Remote register (RWr)
CH.1 check code
CH.2 check code
CH.3 check code
CH.4 check code
CH.5 check code
CH.6 check code
CH.7 check code
CH.8 check code
RWr 0
RWr 1
RWr 2
RWr 3
RWr 5
RWr 6
RWr 7
RWr 8
RWr 9
For station
No. 1
For station
No. 4
FROM
instruction
D200
RWr 4
D201
RWr A
RWr B
CH.1 check code
CH.2 check code
CH.3 check code
CH.4 check code
D202
D203
D204
D205
D206
D207
D208
D209
D210
D211
D212
D213
D214
D215
D216
D217
D218
D219
4C13H
Remote register (RWr)
TO
instruction
FROM
instruction
Ver. 1 compatible
Remote device station
(Station No. 1)
FX
2N-32CCL
Remote register (RWw)
RWw 0
RWw 1
RWw 2
RWw 3
RWw 4
RWw 5
RWw 6
RWw 7
Remote register (RWr)
RWr 0
RWr 1
RWr 2
RWr 3
RWr 4
RWr 5
RWr 6
RWr 7
RWw 8
RWw 9
RWw A
RWw B
RWr 8
RWr 9
RWr A
RWr B
BFM No.
Analog output enable/
prohibit setting
CH.1 to CH.4
output range setting
CH.5 to CH.8
output range setting
HOLD/CLEAR setting
Reserved
D120
D121
D122
D123
Analog output enable/
prohibit setting
CH.1 to CH.4
output range setting
CH.5 to CH.8
output range setting
HOLD/CLEAR setting
Reserved
441BH
CH.6 check code
CH.7 check code
CH.8 check code
CH.5 check code
Error code
Reserved
Reserved
Error code
4C14H
4C15H
Reserved
to
4C1BH
D220
D227
to
to
D124
D127
to
to
to
Reserved
4C00H
4C01H
4C02H
4C03H
4C04H
4C05H
4C06H
4C07H
4C08H
4C09H
4C0AH
4C0BH
4C0CH
4C0DH
4C0EH
4C0FH
4C10H
4C11H
4C12H
4400H
4401H
4402H
4403H
4404H
4405H
4406H
4407H
4408H
4409H
440AH
440BH
440CH
440DH
440EH
440FH
4410H
4411H
4412H
4413H
4414H
4415H
4416H
4417H
4418H

Table of Contents

Other manuals for Mitsubishi FX3U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U and is the answer not in the manual?

Mitsubishi FX3U Specifications

General IconGeneral
SeriesFX3U
Program Capacity64k steps
TypePLC
Power SupplyAC: 100-240V, DC: 24V
I/O PointsUp to 384 points
CommunicationRS-232C, USB, Ethernet
ExpansionSupports multiple expansion modules including I/O, analog, and communication modules
Programming LanguageLadder Logic, SFC, Function Block Diagram
High-speed Processing0.065 μs per basic instruction
Analog I/OAvailable with expansion modules
Positioning ControlUp to 3 axes of positioning control
Weight0.3 kg (Main unit)