App-6
Instruction Condition (Device)
Processing Time (µs)
Q00JCPU Q00CPU Q01CPU
OR < >
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
LD >
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
AND >
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
OR >
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
LD < =
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
AND < =
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
OR < =
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
LD <
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
AND <
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
OR <
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
LD > =
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
AND > =
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
OR > =
When not executed 0.70 0.56 0.35
When executed
In conductive status 0.80 0.64 0.40
In non-conductive status 0.80 0.64 0.40
LDD =
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ANDD =
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ORD =
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
LDD < >
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50
ANDD < >
When not executed 0.80 0.64 0.40
When executed
In conductive status 1.0 0.80 0.50
In non-conductive status 1.0 0.80 0.50

Table of Contents