App-136
Category Instruction Condition (Device)
Processing Time (µs)
L02CPU L26CPU-BT
Min. Max. Min. Max.
Application
instruction
ORTM=
When not executed 0.160 0.038
Comparison of
specified clock
In conductive status 7.300 14.100 6.600 10.800
In nonconductive status 7.300 14.100 6.600 10.800
Comparison of
current clock
In conductive status 6.000 12.700 5.300 9.500
In nonconductive status 6.000 12.700 5.300 9.500
LDTM<>
Comparison of
specified clock
In conductive status 7.600 14.000 6.700 10.800
In nonconductive status 7.600 14.000 6.700 10.800
Comparison of
current clock
In conductive status 6.200 12.700 5.400 9.500
In nonconductive status 6.200 12.700 5.400 9.500
ANDTM<>
When not executed 0.160 0.038
Comparison of
specified clock
In conductive status 7.200 13.900 6.300 10.800
In nonconductive status 7.200 13.900 6.300 10.800
Comparison of
current clock
In conductive status 5.900 12.500 5.100 9.500
In nonconductive status 5.900 12.500 5.100 9.500
ORTM<>
When not executed 0.160 0.038
Comparison of
specified clock
In conductive status 7.300 14.100 6.600 10.800
In nonconductive status 7.300 14.100 6.600 10.800
Comparison of
current clock
In conductive status 6.000 12.700 5.300 9.500
In nonconductive status 6.000 12.700 5.300 9.500
LDTM>
Comparison of
specified clock
In conductive status 7.600 14.000 6.700 10.800
In nonconductive status 7.600 14.000 6.700 10.800
Comparison of
current ciock
In conductive status 6.200 12.700 5.400 9.500
In nonconductive status 6.200 12.700 5.400 9.500
ANDTM>
When not executed 0.160 0.038
Comparison of
specified clock
In conductive status 7.200 13.900 6.300 10.800
In nonconductive status 7.200 13.900 6.300 10.800
Comparison of
current clock
In conductive status 5.900 12.500 5.100 9.500
In nonconductive status 5.900 12.500 5.100 9.500
ORTM>
When not executed 0.160 0.038
Comparison of
specified clock
In conductive status 7.300 14.100 6.600 10.800
In nonconductive status 7.300 14.100 6.600 10.800
Comparison of
current clock
In conductive status 6.000 12.700 5.300 9.500
In nonconductive status 6.000 12.700 5.300 9.500
LDTM<=
Comparison of
specified clock
In conductive status 7.600 14.000 6.700 10.800
In nonconductive status 7.600 14.000 6.700 10.800
Comparison of
current clock
In conductive status 6.200 12.700 5.400 9.500
In nonconductive status 6.200 12.700 5.400 9.500

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals