EasyManuals Logo

Mitsubishi MELSEC Q Series Programming Manual

Mitsubishi MELSEC Q Series
1296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #322 background imageLoading...
Page #322 background image
6-120
BMOV(P)
Caution
While SM237 is on, do not make the following access.
• The indexing target exceeds the device range.
• The value obtained from " to + (n) - 1" is over the boundaries of the device ranges.
• Accessing the file register with file register not set.
• Accessing the area where the multiple CPU high speed transmission area device is not
available (only for the QCPU).
*1: Refer to the DFMOV instruction.
SM237 can be used only for the Universal model QCPU whose first 5 digits of
serial number is 10012 or later and LCPU.
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and
an error code is stored into SD0.
• The device range of n points from or exceeds the corresponding device range.
(Error code: 4101)
D D
S
D